Other Name: Actuator, Air Conditioner Control; HVAC Heater Blend Door Actuator; HVAC Blend Door Actuator; Actuator; Actuator, A/C Vacuum Control; Actuator, A/C Control
Replaces: 16164972
Warranty: This genuine part is guaranteed by GM's
factory warranty.
Fits the following Vehicles:
2000-2013 GMC Yukon XL 2500 | SLE, SLT | 8 Cyl 6.0 L FLEX, 8 Cyl 6.0 L GAS, 8 Cyl 8.1 L GAS
Other Name: Actuator, Air Conditioner Control; HVAC Heater Blend Door Actuator; HVAC Blend Door Actuator; Temperature Door Actuator; Switch; Controller; Actuator; Actuator, A/C Vacuum Control; Actuator, A/C Control
Replaces: 16163982
Warranty: This genuine part is guaranteed by GM's
factory warranty.
Fits the following Vehicles:
2003-2013 GMC Yukon XL 2500 | SLE, SLT | 8 Cyl 6.0 L FLEX, 8 Cyl 6.0 L GAS, 8 Cyl 8.1 L GAS
Other Name: Actuator, Air Conditioner Control; HVAC Heater Blend Door Actuator; HVAC Blend Door Actuator; Actuator; Actuator, A/C Vacuum Control; Actuator, A/C Control
Replaces: 16124922
Warranty: This genuine part is guaranteed by GM's
factory warranty.
Fits the following Vehicles:
2000-2003 GMC Yukon XL 2500 | SLE, SLT | 8 Cyl 6.0 L GAS, 8 Cyl 8.1 L GAS
Other Name: Actuator, Air Conditioner Control; HVAC Heater Blend Door Actuator; HVAC Blend Door Actuator; Actuator, A/C Vacuum Control
Warranty: This genuine part is guaranteed by GM's
factory warranty.
Fits the following Vehicles:
2000-2002 GMC Yukon XL 2500 | SLE, SLT | 8 Cyl 6.0 L GAS, 8 Cyl 8.1 L GAS
GMC Yukon XL 2500 Blend Door Actuator
Our website offers an extensive catalog of genuine GMC Yukon XL 2500 Blend Door Actuator at unbeatable prices. Every OEM GMC Yukon XL 2500 Blend Door Actuator comes with a manufacturer's warranty, an easy return policy, and rapid delivery service. Don't miss out on this great opportunity!
GMC Yukon XL 2500 Blend Door Actuator Parts Questions & Experts Answers
Q: How to replace the right Blend Door Actuator on GMC Yukon XL 2500?
A: The right air temperature actuator replacement begins by disassembling the I/P carrier followed by disconnecting the electrical connector from the actuator. The actuator extraction process starts by unscrewing its fasteners from the HVAC module assembly and carefully removing it from this housing. The new actuator requires placement into the HVAC module assembly before screw installation with 2 N.m (18 lb in) torque following Fastener Notice instructions in Service Precautions. Start by reinstalling the I/P carrier then reattach the electrical connector to the actuator. During the final stage of repair you must follow the actuator recalibration protocols to reprogram the air temperature actuator.